– Advanced Calibration
- 
- Plug in thermocouple into SLT port.
- Calibrate Thermocouple to Ice water 32F.
- Tape thermocouple to side of refrigerant tank that has been sitting at a constant temperature for 24-48 hours.
- Put a brass cap on SLT and another one on LLT and open up both valves.
- Hook up refrigerant tank to manifold and open the tank. (Ensure that the Vac valve is closed on manifold before opening refrigerant tank. 4 port manifold only.)
- Open refrigerant tank
- Select the type of refrigerant being used for this on the manifold.
- Open up the Ref port on manifold (4 port manifold only)
- Both high and low pressures should read the same.
- Press “Test Cal” button.
 
Both pressure sensors should read “GOOD”
 
                 
                 
                 
                 
              