In-Duct Psychrometer Accessory Head - ARH5

The Fieldpiece Voltage Accessory, model AVH1, is designed for use with our data logger model DL3 to record voltage over a period of time or with our EHDL1 electronic handle to get the MIN or Max while freeing up your meter for other tests.User's Manual

Product Flyer

Package Art

Features and Benefits

Competitive Advantages

What's Included?

Specifications

 

 

 

 

What is It?

To assist HVACR professionals in getting the proper measurements, Fieldpiece engineered this in duct psychrometer head to take measurements in the duct where they are supposed to be taken -- near the evaporator!  So HVACR professionals can trust the results for tests like temperature splits, target evaporator exit temperture, target superheat, and CheckMe! because measurements are taken without the interference of outside air temp or leaks in the duct work. 

wireless hvacr meter
* Plus, the ARH5 can make hustling from condensor, to attic, and back again to take indoor wet bulb and charge a system, a thing of the past!  When attached to a wireless transmitter, ARH5 measurements can be sent wirelessly to any Fieldpiece wireless meter (HG3, LT17AW, EH4W) from anywhere on the job site. So results like indoor wet bulb, can be read in real-time on your wireless meter from up to 100' away. 

Like all Fieldpiece products, the ARH5 accessory head was engineered specifically to put the right tools in the hands of HVACR professionals.  For even more convenience and time savings, Fieldpiece designed the 38" telescoping probe with laser etching so techs know the sensor is in the correct location, and is facing in the proper direction.  With the quick-response sensor it's a   snap to complete target superheat, and take target evaporator exit temperature tests.

Features and Benefits

Designed specifically for HVACR professionals, the ARH5 InDuct Psychrometer is a great tool to properly charge fixed restrictor systems.  More than 70% of A/C units are improperly charged, and therefore running inefficienty, but with the ARH5 it's easier to ensure units are running at their maximum efficiency.
  • Measures temperature and %RH
  • Calculates wet bulb and dew point
  • Slim 38" telescoping probe
  • Fast response time
  • Depth and direction indicators
  • Hands-free testing with stabilizing cone and magnetic hanger
  • Can send wireless measurements from up to 100' away

Competitive Advantages

Like all Fieldpiece products, the ARH5 psychrometer was engineering specifically for HVACR professionals.  It makes it easier to get in duct air measurements from the correct location -- near the evaporator.  Plus techs can get their indoor wet bulb measurements in real-time while they are making adjustments at the condensor, via the Fieldpiece wireless transmitter.

What's Included


  • In Duct Psychrometer Accessory Head - ARH5
  • Telescoping Precision Thermistor Probe
  • Stabilizing Cone - RCONE

AVH1-SRC-product-tmb


Recommended Accessories and Replacement Parts

Technicians who like the ARH5 may also enjoy these instruments and accessories:

 

 

Wireless HVAC Guide® System Analyzer - HG3

The Wireless HVAC Guide® System Analyzer, model HG3 and ET2W Wireless Transmitter turn any Fieldpiece Accessory Head into a wireless device.  The new HG3 makes it easy to accurately diagnosis a system because up to 13 measurements can be taken simultaneously to give you real-time data.  Tests include: Target Evaporator Exit Temperature (delta T, evaporator drop, drop across the coil), Target Superheat, Superheat, Subcooling, Combustion Analysis and the CheckMe!® test.  In addition, the HG3 includes automatic calculation of CFM tests for up to 13 grilles, and data logging for up to 13 parameters.

Read More...

Wireless Electronic Handle - EH4W (with ET2W Wireless Transmitter included)

The EH4W Wireless Handle and ET2W Wireless Transmitter connect to any Fieldpiece accessory head to easily make your accessory heads into standalone wireless instruments.  Wireless signals can be sent from up to 75’ away, so you can take your wet bulb measurements and have the live data in your hand while working on the condensor.

SPECIFICATIONS
Wireless range:  Up to 75 feet (23m) line of sight
Wireless Frequency: 910MHz to 920MHz (US), 868.1MHz to 868.5MHz (European)
Display:  5000 count FSTN LCD
Measurement Rate: 2.5 times per second, nominal
Battery life: 200 hrs typical with alkaline
Operating enviroment: 32oF to 122oF (0°C to 50°C) at <70% relative humidity

  

Specifications

TECHNICAL SPECIFICATIONS
Telescoping Probe Length: Up to 38 inches (97cm)
Probe Tip Diameter:
0.35 inch (9mm)
Storage temperature:
-4°F to 140°F (-20°C to 60°C), 0 to 80% RH (with battery removed)
Temperature Coefficient:
0.1 x (specified accuracy)/°C (28°C)
Power:
Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Auto Power Off: 
Approx. 15 minutes
Battery life:
150 hours typical (alkaline)
Low Battery Indication:
Red LO BATT LED will light to indicate low battery
Output Impedance:
500Ω approx.
Dimensions:
144mm(H) x 67mm(W) x 32mm(D)
Weight: 
Approx. 240g, including battery

Temperature:
Sensor type:
Precision thermistor
Operating environment:
-4°F to 140°F (-20°C to 60°C)
Range:
-4°F to 140°F (-20°C to 60°C)
Resolution:
0.1°F / 0.1°C
Accuracy:   
 ±(1°F) 32°F to 113°F
        ±(2°F) -4°F to 32°F, 113°F to 140°F
        ±(0.5°C) 0°C to 45°C
        ±(1°C) -20°C to 0°C, 45°C to 60°C
Output:
1mV to 1°F/°C

Relative Humidity:
Sensor Type:
Capacitance polymer film
Operating environment:
32°F to 131°F (0°C to 55°C)
Range:
0% to 100%RH
Accuracy:    
±(2.5%) 10% to 90%RH
        ±(5%) 90%RH
   
Note: Above accuracies stated at 73.4°F (23°C).
Output:
1mV to %RH
Sensor Response Time:
60 seconds typical for 90% of total range
Sensor Hystersis:
±1%RH typical (Excursion of 10% to 90% to 10%RH)

Normal 0 false false false MicrosoftInternetExplorer4

Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999. 

Overrange: (OL) or (-OL) is displayed.

Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.

Measurement rate: 2.5 times per second, nominal.

Operating Environment: 0°C to 40°C at < 70% relative humidity.

Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.

Auto power off: 15 seconds approx.

Standby consume current: <10μA

Battery: 4 pcs 1.5V (AAA size) UM-4 R03. 

Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor). 

Dimensions: 170mm(H) x 44mm(W) x 40mm(D). 

Weight: 160g including batteries.

 

ELECTRICAL

Range: 20MW, 2000 MW.

Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.

Accuracy:

20 MW range: ±(2%rdg + 2dgts)

2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)

>500 MW ±(5%rdg + 2dgts)

Rated voltage: DC-DC converter to 1000VDC

Accuracy temperature: 23°C ± 5°C less than 70%RH

Temperature Coefficient: 0.1X (specified accuracy)/°C (28°C)