 User's Manual
Product Flyer
Package Art
Features and Benefits
Competitive Advantages
What's Included?
Recommended
Specifications
What is It?
Expandable Manual Ranging Stick Multimeter for HVAC/R with Temp, NCV, Diode Test and more - model HS33 Based on the success of our original stick meter line, the HS33 was designed to measure even more HVAC/R parameters including temperature with quick compensation via a k-type thermocouple plug, a diode test and a built-in non-contact voltage (NCV) tester. The updated ergonomic shape fits firmly and naturally in your hand while testing. A magnetic hanger, along with the detachable test leads and alligator clip probe tips, allow you to remote test and perform other tests hands-free. This is the stick meter schools prefer for their HVAC/R students. It’s got all the basics and more. The rugged rubberized bumpers help this meter stand up to tough conditions in the field. Ranges include VAC, VDC, AAC, ADC, temperature, capacitance (MFD) and a host of other built-in safety features.
How Does it Work?
The HS33 is unique in that it’s a great “starter” meter for new field technicians as well as a top performer for veterans who prefer manual ranging digital multimeters meters. All Fieldpiece accessory heads slide on the top, enabling the user to test a wider variety of parameters from a single meter. All this plus the removable tip test leads make safe one-handed testing a snap. As with all electrical testing, please read the Operator’s Manual and associated safety practices thoroughly before testing and adhere to industry best practices for safety when testing any current carrying device.
Selecting Ranges For DC voltage, set the meter to the VDC parameter instead of VAC (shown below). For all ranges choose a range just above the value you expect. If display reads “OL” (overload), select a higher range. If display shows less than three numbers, select a lower range for better resolution.
|
Voltage

Capacitance

Resistance

Temperature

|
Connecting to Fieldpiece Accessory Heads


1 2
Connect to Fieldpiece accessory heads by simply attaching them to the top of meter (1) or attach remotely through leads (2). For most heads, move dial to mVDC range shown (1). For the AAC clamp (ACH4), move dial to VAC range (2).
Disconnect test leads from voltage before plugging in thermocouple! Insure the temperature being measured is stable. Maintain good contact between the thermocouple and what's being measured.
 The velcro strip supplied is intended to be used as shown on the right. Tie thermocouple like this and wrap Velcro around surface to make sure bare wires are in close contact with surface being measured. This is especially helpful when taking pipe temps.
 The k-type thermocouple supplied is designed with a “wrap tab” to keep the wire out of the way when not needed. Just wrap the wire around tab and pull through the hole at the top to keep in place as shown to the left. No more clutter when stored.
|
Features and Benefits
The HS meter series is unlike any other found in HVAC/R. We incorporate a number of safety features, both those you can and can’t see, into our meters. In addition, the HS series accepts modular test instrument accessory heads. The HS33 is the first evolution of the stick meter concept. While the function of the meter is similar to the orgonal stick meter line, we’ve updated it since its introduction to include a number of features that make the HVAC/R technicians job easier, better and safer.
Non-contact Voltage With the red NCV tab on the tip of the meter close to an AC voltage, press and hold the NCV button. The NCV LED will light with an analog feel and the beeper will beep. The closer you get to AC voltage, the louder the beep. The NCV function is sensitive enough to detect 24VAC on thermostats.
The non-contact voltage feature can be used in conjunction with one probe tip to find which wire is live. With meter set to OFF, place probe tip in red plug as shown below. Hold down NCV while touching each wire, a noticeably louder buzz will sound when you’ve touched a live wire.
400AAC Using the included amp clamp accessory, model ACH4, on the 200 mVAC range allows you to read 0-400 amps directly on your meter with 0.1 resolution. Use it with the detachable test leads to remote the amp clamp and test with the blower door closed for more accurate readings.
Capacitance For motor-start and motor-run capacitors. Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor.
High Voltage and Continuity Indicators In any VAC/VDC range, when you touch a voltage greater than 30V, the beeper will beep and the red Hi-V LED will signal you. BE CAREFUL! The continuity beeper and green LED tell you if the circuit you’re testing is open or closed.
MIN / MAX and Data HOLD Press MIN/MAX once to begin recording MIN and MAX. Press MIN/MAX to select current reading’s MIN or MAX. Hold down for 2 seconds to exit MIN/MAX function. Press HOLD to hold data.
Silicone Leads with Detachable Probe Tips Because the wire insulation is silicone the leads will stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Detachable probes tips and the modular design of the HS33 allow you to plug V lead tip into the top of the meter, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most any meter on the market.
And More:
- Rugged ABS case with rubberized bumpers.
- Built-in magnetic hanger allows you to test with one hand or no-hands.
- Built-in lead storage.
- Ergonomic shape fits naturally in your hand.
- Auto power-off (APO) to conserve battery life.
Competitive Advantages
The features and benefits are the competitive advantages when it comes to the HS33. This is truly an HVAC/R multimeter.
It wasn’t too long ago that the only multimeter you could buy was designed for lab use. Today’s HVAC/R technician can buy meters with functions and features specifically designed for field use. And, they’re more rugged, convenient, and safe. Clips for one-handed testing. Loud BEEPERS and bright LEDS to warn of dangerous voltages, even in noisy environments. Magnetic hangers. Automatic HOLD and MAX so eyes stay focused on the test point. Silicone leads. Manual ranging.
Plus modular expandability allows you to take a truckload of test instruments to the job in a bag over your shoulder.
What's Included
- Expandable Manual Ranging Stick Multimeter for HVAC/R - HS33
- 400A Amp Clamp Accessory - ACH4
- Deluxe Silicone Test Leads - ADLS2
- Short Alligator Lead Extensions - ASA2
- Deluxe Meter Case - ANC1
- 9-Volt battery (installed)
- Operator’s manual
|
|
Recommended Accessories and Replacement Parts
Technicians who like the HS33 may also enjoy these instruments and accessories:
|

|
Superheat and Subcooling Accessory for Air Conditioning – ASX14
The Fieldpiece Superheat and Subcooling Accessory for Air Conditioning, model ASX14, measures suction line, or low side, line temperature and pressure. It then calculates actual superheat in real time using built in P/T charts. It also measures liquid line, or high side, line temperature and pressure, and calculates actual subcooling. Use it to get actual superheat on R-22 and R-410A fixed orifice systems and actual subcooling on TXV / TEV regulated systems. Use the “T” fitting to charge to actual superheat or subcooling by putting the ASX14 in-line between your refrigerant bottle and the system.
Read More..
|
|

|
Digital Sling Psychrometer Accessory - ARH4
The Fieldpiece model ARH4 Digital Sling Psychrometer and Hygrometer Accessory Head measures both relative humidity and ambient air temperature. It calculates dew point and wet bulb. It’s great for calculating target superheat as well as logging %RH, temp, WB or DP over time. The head converts %RH, ambient temperature, dew point temperature, and wet bulb temperature to a voltage at a rate of 1 %RH or degree to 1mVDC and your reading is displayed on your meter. The ARH4 snaps directly onto Fieldpiece stick meters, data logger, electronic handles and adapters.
Read More..
|
 |
Dual-Port Manometer Accessory – ADMN2
The ADMN2 is a portable dual port manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure, static pressure and pressure differential. The ADMN2 includes a zero adjust and the Auto Power-Off (APO) function conserves battery life. Disable APO for data logging. The ADMN2 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The ADMN2 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of 0.01inWC or 0.01mBar.
Read More..
|
|

|
Large Briefcase-Style Instrument Bag – ANC3
The ANC3 Large Briefcase-Style Instrument Bag is our top of the line instrument case. Combined with our modularly expandable instruments and accessories, the ANC3 can haul a service truck full of tools to your job, over your shoulder. It has 14 pockets in all. It holds most any combination of your Fieldpiece gear: 3 meters and 10 accessory head instruments with room for plenty more, or, put in 6 standalones and their accessories, 2 meters and more. The combinations are almost endless. One thing’s for sure, you can fit the test instruments you need to do the whole job easier, better and faster with the ANC3 over your shoulder. Features include rugged nylon construction, padding, durable pockets inside and out, a rugged zippers and a shoulder strap. Comes standard with our big Fieldpacks and doubles as a great laptop briefcase.
Read More..
|
Specifications
TECHNICAL SPECIFICATIONS Display: 3½ digit liquid crystal display (LCD) with a maximum reading of 1999. Overrange: "OL" mark indication. Auto power off: 60 minutes. Operating environment: 32 to 122°F (0 to 50°C) at <70% R.H. Storage temperature: -4 to 140°F (-20 to 60°C), 0 to 80% R.H. with battery removed. Accuracy: Specifications good in ambient conditions of 73°F ±9°F (23°C ±5°C), <75% relative humidity. Temperature Coefficient: 0.1×(specified accuracy) per °F/°C. (32 to 64°F (0 to 18°C), 82 to 122°F (28 to 50°C)). Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22. Battery life: 300 hours typical with alkaline. Accessories: One pair test leads, one pair alligator clips, k-type thermocouple (HS33), 9V battery (installed), and operating instructions. Safety: UL, CE, Cat III 600V, UL3111, IEC/EN61010-1, C-Tick certified.
Diode test Test current: ~1.0mA Accuracy: ±(1.5% rdg + 3 dgts) Open circuit volts: 3.0VDC typical Overload protection: 500VDC or AC rms
Continuity Audible indication: Less than 100Ω Response time: 100ms Green LED will be on continuously. Overload protection: 500VDC or AC rms
Capacitance Range: 200μF Resolution: 0.1μF Accuracy: ±(3% rdg + 5 dgts) Overload protection: 500VDC or AC rms
DC volts Ranges: 200mV, 2000mV, 200V Resolution: 0.1mV Accuracy: ±(0.5% rdg + 1 dgt) Input impedance: 560kΩ on V inputs, 10MΩ on mV input Overload protection: 600VDC or AC rms, 500VDC/350VAC rms 15 sec on 200mV range Transient protection: 6kV for 10μ sec
AC volts (50Hz - 500Hz) Ranges: 200mV, 200V, 600V Resolution: 0.1mV Accuracy: ±(1.2% rdg + 3 dgts) ±(2.0% rdg + 5 dgts) on 600V range Input impedance: 560kΩ on V input, 10MΩ on mV input Overload protection: 600V DC or AC rms Transient protection: 6kV for 10μ sec
Resistance Ranges: 200Ω, 200kΩ Resolution: 0.1Ω Accuracy: ±(1.0% rdg + 4 dgts) Open circuit volts: 0.3VDC typical, (3.0VDC on 200Ω range) Overload protection: 500VDC or AC rms
Temperature Range: -30 to 200°F (-34 to 93°C) Resolution: 0.1°F/°C Accuracy: ±1°F, 32 to 120°F (0 to 48°C), ±1% + 1.5°F, -4 to 200°F (-20 to 93°C), ±2% + 3°F, -30 to -4°F (-34 to -20°C). Sensor type: K-type thermocouple Overload protection: 60 VDC or 30 VAC rms
Field °F calibration For accuracies of ±°F, calibrate the HS33 to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used.
- Select the 200°F range.
- Remove back case and hold the battery in place with a rubber band so terminals are touching.
- Stabilize a large cup of ice water.
- Immerse the thermocouple probe and let it stabilize.
- Adjust VR3 (below battery) to get close to 32°F (0°C) then adjust VR1 (right of battery) to get within 0.1°F (0.1°C) of 32.0°F (0.0°C).
- To calibrate in °C, close the jumper that is just below VR1.
|