Milliamps & Microamp Accessory - AUA2

The Fieldpiece Milliamps & Microamp Accessory, model AUA2, converts microamps (for flame rectifier diode) and milliamps (for heat anticipators and more) to a mV signal for direct current reading on any meter with mV ranges.User's Manual

Package Art

Ad

Features and Benefits

Competitive Advantages

What's Included?

Recommended

Specifications

 

 

 

 

What is It?

Solve those “no heat” calls fast and efficiently with the Fieldpiece Milliamps & Microamp Accessory, model AUA2. The head converts microamps (for flame rectifier diode) and milliamps (for heat anticipators and control circuits) to a mV signal for direct current reading on any meter with mV ranges. For resolution of 0.1 micro/milliamps, use a meter that displays 0.1mV. The AUA2 includes quick connect and mini-plug adapters to convert your "stick" meter, DL3 data logger, and EHDL1 electronic handle to a one-piece flame rectifier diode tester and heat anticipator checker.

 

How Does it Work?

The AUA2 accessory converts microamps and milliamps to a mV signal for direct current reading on any meter with mV ranges. Use it for flame rectifier diode tests, heat anticipator and control circuit checks.

OperationAUA2-flame-diode
  1. Connect the AUA2 to meter’s COM and VOLTS plugs. Connect through leads or slide head onto meter.
  2. Break flame rectifier diode circuit and connect AUA2 in series using the appropriate adapter. You can also use industry standard leads.
  3. Select microamps (for flame rectifier diode) or milliamps on the front of AUA2.
  4. Set the meter to mV AC or DC range to directly read micro/milliamps.

 

Features and Benefits

Measures milliamps and microamps for flame diode test. Measures 4 to 20mA control circuits.
  • Includes flame diode adapter kit (AQK3).
  • Resolution: 0.1 for meters with 0.1mVDC.
  • Accuracy: DC: ±(1.0%rdg + 1dgt) AC: ±(1.5% + 2dgts).
  • Max current: 200mA AC or DC.

 

Competitive Advantages

Like all of the Accessory Head model instruments that Fieldpiece designs, the AUA2 gives you the ability to do more work from one small bag of tools.  It is the only modular current instrument of its kind and provides you with valuable data in diagnosing “no heat” calls in the field when used with our meters, data logger and electronic handle.

What's Included


  • Milliamps & Microamp Accessory - AUA2
  • Flame Diode Lead Kit - AQK3
  • Operator’s manual

AUA2-SRC-product-KIT-tmb


Recommended Accessories and Replacement Parts

Technicians who like the AUA2 may also enjoy these instruments and accessories:

 

HS33-SRC-product-tmb

Expandable Manual Ranging Stick Multimeter for HVAC/R - HS33

Based on the success of our original stick meter line, the HS33 was designed to measure even more HVAC/R parameters including temperature with quick compensation via a k-type thermocouple plug, a diode test and a built-in non-contact voltage (NCV) tester. The updated ergonomic shape fits firmly and naturally in your hand while testing. A magnetic hanger, along with the detachable test leads and alligator clip probe tips, allow you to remote test and perform other tests hands-free.  This is the stick meter schools prefer for their HVAC/R students. It’s got all the basics and more. VAC, VDC, AAC, ADC, temperature, capacitance (MFD) and a host of other built-in safety features.

Read More..

EHDL1-SRC-product-tmb

Electronic Handle - EHDL1

Convert any Fieldpiece accessory head instrument into a standalone with the Electronic Handle model EHDL1. It features a MAX/MIN button to record the highest and lowest reading. And a HOLD button to hold the reading. The EHDL1 has a 200 and 2000 mVAC for use with our Amp Clamp, model ACH4 and the 200 and 2000mVDC range is for use with the rest of our accessory head instruments.

 

Read More..

ANC1-SRC-product-tmb

Deluxe Meter Case - ANC1

The Deluxe Meter Case, model ANC1, easily holds 1 meter and 2 accessory head instruments. Features include rugged nylon construction, padding, durable pockets inside and out, a rugged double zipper and a shoulder strap. The ANC1 comes standard with our HS30 Series Stick Multimeters.

 

Read More..


Specifications

TECHNICAL SPECIFICATIONS
Conversion rate: 1mV/1mA, 1mV/1μA
Resolution: 0.1 for meters with 0.1mVDC
Accuracy: (at 73ºF ± 10ºF 95%RH)
DC: ±(1.0%rdg + 1dgt)
AC: ±(1.5% + 2dgts)
Max current: 200mA AC or DC
Overload protection: 0.25A/600V (6x32mm) fast blow fuse, Fieldpiece part # RFM66.
Operating temp: 32ºF to 120ºF at <95%RH
Storage temp: -4ºF to 140ºF
Safety: CE- mark approved, EN61010-1 approval, Cat III 600V

Normal 0 false false false MicrosoftInternetExplorer4

Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999. 

Overrange: (OL) or (-OL) is displayed.

Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.

Measurement rate: 2.5 times per second, nominal.

Operating Environment: 0°C to 40°C at < 70% relative humidity.

Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.

Auto power off: 15 seconds approx.

Standby consume current: <10μA

Battery: 4 pcs 1.5V (AAA size) UM-4 R03. 

Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor). 

Dimensions: 170mm(H) x 44mm(W) x 40mm(D). 

Weight: 160g including batteries.

 

ELECTRICAL

Range: 20MW, 2000 MW.

Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.

Accuracy:

20 MW range: ±(2%rdg + 2dgts)

2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)

>500 MW ±(5%rdg + 2dgts)

Rated voltage: DC-DC converter to 1000VDC

Accuracy temperature: 23°C ± 5°C less than 70%RH

Temperature Coefficient: 0.1X (specified accuracy)/°C (28°C)