Accessory Heads
Connect Fieldpiece accessory heads to the “stick” meter, data logger, electronic handle, or other DMM to measure HVAC/R parameters. The Fieldpiece HS series “stick” meters connect directly to accessory heads by sliding the head right onto the meter. Use the EHDL1 handle to convert any head to a stand alone meter. Fieldpiece accessory heads can be used with most other DMMs. Your meter only needs mV (AC and DC) ranges and industry standard input jacks. Use the Fieldpiece deluxe test leads (ADLS2) or the convenient AHDL1 adapter handle to connect the head to your meter.


The AAV3 anemometer head measures air velocity and temperature. It’s great for estimating CFM and quickly balancing conditioned space.

Anemometer Head - AAV3

The AAV3 is an anemometer accessory head for use with our modular instruments that measures air velocity and temperature in English or Metric units: Ft/min, M/s, MPH, KM/hr, ºF (degrees Fahrenheit) or ºC (degrees Celsius). Multiply your air velocity by the register’s free area to estimate CFM or diagnose duct blockages and quickly check the airflow balance in a conditioned space. Use with our DL3 Data Logger to track airflow or temperature over time. Features average and real time testing modes.

Read More..

 

 

The ACDC6 enables technicians to measure up to 600A AC or DC current on most multimeters with industry standard jacks.

600A AC DC Current Clamp Accessory - ACDC6

The ACDC6 is a high-current AC / DC Current Clamp Accessory that gives technicians more flexibility when testing line current. Measures up to 600A AC or DC. The clamp enables most multimeters to measure current without breaking the circuit. The jaw opens to 1.18 inches (3 cm). A coiled cable keeps clutter out of the testing area, Quickly zero out the clamp using the adjustable dial on the face. Use with any multimeter with industry standard Volt and COM jacks and mV AC and DC ranges. Green mechanical contractors tell us they are also using the clamp to measure high-current lines on integrated solar panel powered HVAC / hot water systems.

Read More..

 

 

The ACH4 enables technicians to measure up to 400A AC current on most multimeters with industry standard jacks.

400A Amp Clamp Accessory - ACH4

The ACH4 current clamp is a small size accessory head for quickly reading up to 400 AC amps. The new claw feature at the top of the clamp allows for quickly picking out the wire you need to measure and isolating it in the clamp. Once the current carrying conductor is isolated, the amperage is converted to mVAC for reading directly on the meter. The ACH4 works with the Fieldpiece “Stick” meter, EHDL1 Electronic Handle, DL3 Data Logger, the HVAC Guide® System Analyzer or any other digital multimeter (with mVAC range) connected by Fieldpiece ADLS2 detachable silicone leads or AHDL1 handle adapter.

Read More..

 

 

The ACM3 has a fast electrochemical sensor specific to carbon monoxide or CO. It measures CO in parts per million (0-1000 ppm, 2000 ppm max 5 min. exposure time)

Carbon Monoxide Detector Accessory - ACM3

The ACM3 is a carbon monoxide detector (CO detector) accessory head for use with our modular instruments that measures CO in parts per million (ppm). Its electrochemical sensor is fast enough for walk-around tests. Features and benefits include: Advanced, three-pin sensor that measures 0 to 1000 ppm CO; Calibrate / Zero ACM3 to ambient quickly with the zero calibration pot under the grey rubber strip; Auto Power-Off (APO); Use optional pump (AOXP2) for remote / flue gas testing.

Read More..

 

 

The ADMN2 dual port manometer measures gas pressure, static pressure and pressure differential.

Dual-Port Manometer Accessory - ADMN2

The ADMN2 is a portable dual port manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure, static pressure and pressure differential. The ADMN2 includes a zero adjust and the Auto Power-Off (APO) function conserves battery life. Disable APO for data logging. The ADMN2 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The ADMN2 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of 0.01inWC or 0.01mBar.

Read More..

 

 

The AMN2 dual port manometer measures gas pressure and static pressure.

Manometer Accessory - AMN2

The AMN2 is a portable dual port manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure with a resolution for static pressure measurements. The AMN2 includes a zero adjust and the Auto Power-Off (APO) function conserves battery life. Disable APO for data logging. The AMN2 measures pressure between -60inWC and 60inWC (inches of water column). Take static pressure measurements using the resolution mode of 0.01inWC. Special purpose static pressure instruments are on the market with better accuracy and temperature compensation, but they typically cost much more than the AMN2.

Read More..

 

 

The AOX2 Combustion Check head gives technicians all of the test parameters they need for everyday combustion testing without all of the costly extras they don't need. Measures % O2 and Flue Temp, Calculates % CO2 for Oil and Gas equipment.

Combustion Check Accessory - AOX2

The AOX2 is combustion check accessory head that measures % O2 (percent oxygen) and flue gas temperature. It calculates % CO2 (percent carbon dioxide) for two fuel types: gas and oil. Technicians use the AOX2 to sample flue gas on serviced or newly installed equipment. It eliminates the costly, extra tests found on full-function combustions analyzers that technicians often don’t use or need. Match your results to specifications on the data plate or in the manufacturer’s manual to quickly tune furnaces, boilers and more.

Read More..

 

 

The ARH4 Digital Sling Psychrometer measures relative humidity and temperature. It also calculates wet bulb and dew point.

Digital Sling Psychrometer Accessory - ARH4

The Fieldpiece model ARH4 Digital Sling Psychrometer and Hygrometer Accessory Head measures both relative humidity and ambient air temperature. It calculates dew point and wet bulb. It’s great for calculating target superheat as well as logging %RH, temp, WB or DP over time. The head converts %RH, ambient temperature, dew point temperature, and wet bulb temperature to a voltage at a rate of 1 %RH or degree to 1mVDC and your reading is displayed on your meter. The ARH4 snaps directly onto Fieldpiece stick meters, data logger, electronic handles and adapters.

Read More..

 

 

The Superheat Accessory for Air Conditioning – model ASH3 measures suction line temperature and pressure. It calculates ACTUAL superheat in real time.

Superheat Accessory for Air Conditioning - ASH3

The Fieldpiece Superheat Accessory for Air Conditioning – model ASH3 measures suction line, or low side, line temperature and pressure and calculates ACTUAL superheat in real time. Use it to get ACTUAL superheat on R-22 and R-410A fixed orifice systems. On systems regulated with a TXV / TEV you’ll want to look at our ASX14, ASX24 and SSX34 superheat and subcooling instruments. Use the “T” fitting to charge to actual superheat by putting the ASH3 in-line between your refrigerant bottle and the system.

Read More..

 

 

The Superheat Accessory for Air Conditioning – model ASX14 measures suction line or liquid line temperature and pressure. It calculates ACTUAL superheat in real time.

Superheat and Subcooling Accessory for Air Conditioning - ASX14

The Fieldpiece Superheat and Subcooling Accessory for Air Conditioning, model ASX14, measures suction line, or low side, line temperature and pressure. It then calculates actual superheat in real time using built in P/T charts. It also measures liquid line, or high side, line temperature and pressure, and calculates actual subcooling. Use it to get actual superheat on R-22 and R-410A fixed orifice systems and actual subcooling on TXV / TEV regulated systems. Use the “T” fitting to charge to actual superheat or subcooling by putting the ASX14 in-line between your refrigerant bottle and the system.

Read More..

 

 

The Superheat Accessory for Refrigeration – model ASX24 measures suction line or liquid line temperature and pressure. It calculates ACTUAL superheat in real time.

Superheat and Subcooling Accessory for Refrigeration - ASX24

The Fieldpiece Superheat and Subcooling Accessory for Refrigeration, model ASX24, measures suction line, or low side, line temperature and pressure. It then calculates actual superheat in real time using built in P/T charts. It also measures liquid line, or high side, line temperature and pressure, and calculates actual subcooling. Use it to get actual superheat and subcooling on R134A and R404A systems. Use the “T” fitting to charge to actual superheat or subcooling by putting the ASX24 in-line between your refrigerant bottle and the system.

Read More..

 

 

Dual-Temperature Accessory – model ATH4 measures suction line or liquid line temperature and pressure. It calculates ACTUAL superheat in real time.

Dual-Temperature Accessory - ATH4

The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters. Use wet and dry bulb thermocouples to find target superheat.

Read More..

 

 

Non-Contact Infrared Temperature Accessory with Laser Sight – model ATIR3 collects the average infrared energy within its 8:1 cone of view and converts it to a mVDC signal that is proportional to the temperature being measured.

Non-contact Infrared Temperature Accessory with Laser Sight - ATIR3

The Fieldpiece Non-contact Infrared Temperature Accessory with Laser Sight, model ATIR3, collects infrared energy (IR) and converts it to a mVDC signal that is proportional to the temperature being measured. The temperature measured is the average of all the temperatures in the 8:1 cone of viewability. The closer you are to the target, the smaller the area measured. The further away, the larger the area. The digital, non-contact ATIR3 converts the Fieldpiece “Stick” series meter, DL3 data logger, and EHDL1 electronic handle to a one-piece infrared, or IR, thermometer. Use the optional Fieldpiece ADLS2 deluxe silicone test leads or the AHDL1 adapter handle with the ATIR3 for use with DMMs with industry standard jacks.

Read More..

 

 

The Fieldpiece Milliamps & Microamp Accessory, model AUA2, converts microamps (for flame rectifier diode) and milliamps (for heat anticipators and more) to a mV signal for direct current reading on any meter with mV ranges.

Milliamps & Microamp Accessory - AUA2

The Fieldpiece Milliamps & Microamp Accessory, model AUA2, converts microamps (for flame rectifier diode) and milliamps (for heat anticipators and control circuits) to a mV signal for direct current reading on any meter with mV ranges. For resolution of 0.1 micro/milliamps, use a meter that displays 0.1mV. The AUA2 includes quick connect and mini-plug adapters to convert your "stick" meter, DL3 data logger, and EHDL1 electronic handle to a one-piece flame rectifier diode tester and heat anticipator checker.

Read More..

 

 

The Digital Vacuum Gauge Accessory – model AVG2 measures pressure from 50 to 2000 microns of mercury and converts it to a proportional mVDC signal for display on your compatible DMM,

Digital Vacuum Gauge Accessory - AVG2

The Fieldpiece Digital Vacuum Gauge Accessory, model AVG2, is a thermistor based digital multimeter accessory that digitally measures a vacuum of 50 to 2000 microns and converts that reading into millivolts DC on your compatible DMM or our electronic handle and data logger. LEDs provide a pump down indicator showing progress from atmospheric pressure. The sensor has been designed to withstand pressures up to 500 psi (3400kPa) so that no damage to the AVG2 will occur if it is exposed to full system pressures.

Read More..

 

 

The Fieldpiece Voltage Accessory, model AVH1, is designed for use with our data logger model DL3 to record voltage over a period of time or with our EHDL1 electronic handle to get the MIN or Max while freeing up your meter for other tests.

Voltage Accessory - AVH1

The Fieldpiece Voltage Accessory, model AVH1, converts volts to millivolts for use with data logger DL3 for direct display and recording of voltage through the meter’s mV scale. Use it with the EHDL1 to record MIN and MAX while freeing up your meter for other tests. Cat III rated. Maximum voltage of 600V AC or DC.