 User's Manual
Product Flyer
Package Art
Features and Benefits
Competitive Advantages
What's Included?
Specifications
What is It?
The LT17AW Digital Multimeter is loaded with the parameters and ranges you need for HVACR troubleshooting, plus it receives measurements wirelessly from any of the Fieldpiece Accessory Heads when they are connected to the wireless transmitter that's included. You can now easily measure current, resistance, voltage, capacitance, frequency, continuity, and temperature either directly, or wirelessly from up to 75' away.
Because of the wireless capability you can connect your amp clamp and completely close the blower door so you get a more accurate amperage reading. Or you can set up a wet bulb measurement in the attic and get live readings while you're making adjustments at the condenser. 
Features and Benefits
Designed specifically for HVACR field service, the LT17AW combines wireless readings with specific features and benefits that HVACR field service pros need.
Transforms any Fieldpiece Accessory Head into a Wireless Device There is a Fieldpiece accessory head available for just about any job. There are heads to measure temperature, superheat, subcooling, RH%, wet bulb, dew point, vacuum (microns of mercury), manometer (inches of water column), amps AC&DC, high voltage, CO, %CO2, air velocity, and many more.
| Transmitter and ACH4 Clamp |
Now with the wireless LT17AW all accessory heads can be used either directly through tests leads, or wirelessly with the ET2W wireless transmitter that's included with your LT17AW.
Continuity Indicator If you were doing lab testing, these features would probably drive you crazy. We’ve heard from more than one HVACR veteran that these features really remind you of what you’re doing and they’ve avoided potentially dangerous situations in the field. The Hi-V LED and beeper let you know when you’ve hooked up to a circuit over 30V. The continuity LED and beeper tells you if a circuit is open or closed. 400AAC Using the detachable test leads and the accessory head amp clamp, read 0-400 amps directly on your meter.
Capacitance (MFD) Measure microfarads on motor-run and motor-start capacitors using this range. Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation.
Temperature Take ambient air or refrigeration line temperatures and more with the built-in K-type port and the included ATB1 wrap tab thermocouple. Add a wet sock (saturated tissue or a shoelace to take wet bulb temperatures. The built-in temperature junction offers great temperature compensation for more accurate and faster measurements,
Microamps DC - Flame Rectification Tests The most common ‘no heat” call has to do with a malfunctioning flame sensing diode. Simply turn the meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly.
Frequency Measure from 10Hz to 40kHz using this range with 1 Hz resolution.
Silicone Leads with Detachable Probe Tips Because the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Use the either probe clip on rubber boot to connect and firmly hold the V lead in place, detach the COM probe tip, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job. Tilt Stand and Magnetic Hanger One thing we hear from technicians every day is how much they enjoy the magnetic hanger because it keeps the meter out of the way while testing. The LT17A includes the magnet and a tilt stand to give you a choice in the way you want to use it. Bright Blue Backlight Easily read the display in overcast conditions or in dimly lit areas. MAX/MIN hold Record the minimum or maximum reading during a measurement. To exit the MIN/MAX function, hold the button for more than 2 seconds And More:
- Volts AC.
- Volts DC.
- Resistance (Ohms).
- Diode Test
- Rugged ABS case with rubber boot.
- Even though it’s a classic style meter it still fits naturally in your hand.
- Auto power-off (APO) to conserve battery life.
Competitive Advantages
The testing capability packed into this classic style meter is its main competitive advantage. In addition to all of the ranges, it has direct temperature measurement and it works with all of our accessory head instruments to make it one of the most complete classic style meters available for HVACR. Add to that the fact that the classic design still fits naturally in your hand and comes standard with a rugged rubber boot. We think the boss got it right when he said this is the “Biggest Bang for The Buck”.
What's Included
- Digital Multimeter - LT17AW
- Wireless Transmitter - ET2W
- Current Clam Head - ACH4
- Deluxe Test Leads - ADLS2
- K-type Thermocouple - ATB1
- Large Single Meter Case - ANC9
- Operator’s manual
|
|
Specifications
TECHNICAL SPECIFICATIONS
Wireless Range: Upto 75 feel (23m) line of sight Wireless Frequency: 910MHz to 920MHz (US), 868.1MHz to 868.5MHz (European) Display: 5000 count liquid crystal display with backlight Auto-off: off after 30 minutes to extend battery. Indicators: Continuity beeper (<100Ω). Low bat. Overrange: "OL" or “-OL” is displayed. Operating environment: 32 to 122°F (0 to 50°C) <70%RH Storage environment (with batteries removed): -4 to 140°F (-20 to 60°C) <80%RH Altitude: 6561.7 feet (2000m). Battery life: 100 hours typical. Battery type: 9V NEDA 1604 type Stated accuracies: 74°F±8°F (23°C±4°C), 75%RH Temperature coefficient: 0.1 x (specified accuracy) 1°F/°C (32 to 66°F (0 to 19°C), 82 to 122°F (28 to 50°C)).
DC Voltage Ranges: 500mV, 5000mV, 50V, 500V, 600V Resolution: 0.1mV Accuracy: 0.5%±3 Input impedence: 10MΩ
AC Voltage (50Hz-500Hz) Ranges: 500mV, 5000mV, 50V, 500V, 600V Resolution: 0.1mV Accuracy: 1.2%±6(500mV to 50V ranges), 2%±6(500V and 600V ranges) Input impedence: 10MΩ
DC Current (through meter) Ranges: 500μA, 50mA, 500mA Resolution: 0.1μA Accuracy: 1.0%±1 Voltage burden: 800mV
AC Current (through meter) Ranges: 500μA, 50mA, 200mA Resolution: 0.1μA Accuracy: 1.5%±4 Voltage burden: 800mV
Frequency (autoranging) Range: 10Hz to 40KHz Resolution: 1Hz Sensitivity: 3.5V rms min Accuracy: 0.1%± 3
Resistance (ohms) Ranges: 200Ω, 2kΩ, 200kΩ, 20MΩ Resolution: 0.1Ω Accuracy: 1.0%±4 (200Ω to 200kΩ ranges), 2.0%±4 (20MΩ range) Open circuit voltage: 0.3VDC typical, (2.5VDC on 200Ω)
Diode Test Accuracy: 1.5%±3 Test current: 0.5mA approx. Open circuit voltage: 2.5VDC typical
Capacitance (MFD) Ranges: 20μF, 200μF, 2kuF Resolution: 0.01μF Accuracy: 4%±10 Test frequency: 21Hz Test voltage: <3.0V
Temperature Ranges: -30 ~ 1400°F (-35 ~ 750°C) Resolution: 0.1°F, 0.1°C Accuracy: ±(1°F) 32 ~ 120°F ±(1.0%+1.5°F) 32°F ~ 750°F ±(3.0%+4°F) -30 ~ 32°F, 750 ~ 1400°F ±(1°C ) 0°C ~ 49°C; ±(1.0% + 1°C) 0°C ~ 399°C; ±(3.0% + 3°C) -35°C ~ 0°C; 400°C ~ 750°C Sensor type: K-type thermocouple
Field Calibration (temp offset pot) The LT17AW can be easily calibrated on the job. Use a bucket of ice water to have a known 32°F (0°C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0).
Fuse Replacement: When only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection values below. If that doesn’t work visit our Warranty Page.to check for other problems.
Overload Protection VAC/DC: (500mV range ) 600VAC/DC rms for 15 sec (>500mV range) 600VAC/DC rms AAC/DC: 0.25A/500V fuse (6.3X32mm) Capacitance: 0.25A/500V fuse (6.3X32mm) model RFM66 Temperature: 30VAC/DC rms Resistance: 500VAC/DC rms Diode Test: 500VAC/DC rms Continuity: 500VAC/DC rms
Normal 0 false false false MicrosoftInternetExplorer4
Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999.
Overrange: (OL) or (-OL) is displayed.
Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.
Measurement rate: 2.5 times per second, nominal.
Operating Environment: 0°C to 40°C at < 70% relative humidity.
Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.
Auto power off: 15 seconds approx.
Standby consume current: <10μA
Battery: 4 pcs 1.5V (AAA size) UM-4 R03.
Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor).
Dimensions: 170mm(H) x 44mm(W) x 40mm(D).
Weight: 160g including batteries.
ELECTRICAL
Range: 20MW, 2000 MW.
Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.
Accuracy:
20 MW range: ±(2%rdg + 2dgts)
2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)
>500 MW ±(5%rdg + 2dgts)
Rated voltage: DC-DC converter to 1000VDC
Accuracy temperature: 23°C ± 5°C less than 70%RH
Temperature Coefficient: 0.1X (specified accuracy)/°C (28°C)
|