Wireless Digital Multimeter - LT17AW

The Fieldpiece Voltage Accessory, model AVH1, is designed for use with our data logger model DL3 to record voltage over a period of time or with our EHDL1 electronic handle to get the MIN or Max while freeing up your meter for other tests.User's Manual

Product Flyer

Package Art

Features and Benefits

Competitive Advantages

What's Included?

Specifications

 

 

 

 

What is It?

The LT17AW Digital Multimeter is loaded with the parameters and ranges you need for HVACR troubleshooting, plus it receives measurements wirelessly from any of the Fieldpiece Accessory Heads when they are connected to the wireless transmitter that's included.  You can now easily measure current, resistance, voltage, capacitance, frequency, continuity, and temperature either directly, or wirelessly from up to 75' away.  

Because of the wireless capability you can connect your amp clamp and completely close the blower door so you get a more accurate amperage reading.  Or you can set up a wet bulb measurement in the attic and get live readings while you're making adjustments at the condenser. 

Features and Benefits

Designed specifically for HVACR field service, the LT17AW combines wireless readings with specific features and benefits that HVACR field service pros need.

Transforms any Fieldpiece Accessory Head into a Wireless Device
There is a Fieldpiece accessory head available for just about any job. There are heads to measure temperature, superheat, subcooling, RH%, wet bulb, dew point, vacuum (microns of mercury), manometer (inches of water column), amps AC&DC, high voltage, CO, %CO2, air velocity, and many more.

Transmitter and ACH4 Clamp

Now with the wireless LT17AW all accessory heads can be used either directly through tests leads,     or wirelessly with the ET2W wireless transmitter that's included with your LT17AW.               


Continuity Indicator
If you were doing lab testing, these features would probably drive you crazy.  We’ve heard from more than one HVACR veteran that these features really remind you of what you’re doing and they’ve avoided potentially dangerous situations in the field.  The Hi-V LED and beeper let you know when you’ve hooked up to a circuit over 30V.  The continuity LED and beeper tells you if a circuit is open or closed.
 
400AAC
Using the detachable test leads and the accessory head amp clamp, read 0-400 amps directly on your meter.  

Capacitance (MFD)
Measure microfarads on motor-run and motor-start capacitors using this range.  Disconnect the capacitor from power first. Short the terminals to discharge the capacitor. Disconnect any resistors that might be between the terminals of the capacitor and measure to check for degradation.

Temperature  
Take ambient air or refrigeration line temperatures and more with the built-in K-type port and the included ATB1 wrap tab thermocouple. Add a wet sock (saturated tissue or a shoelace to take wet bulb temperatures. The built-in temperature junction offers great temperature compensation for more accurate and faster measurements,

Microamps DC - Flame Rectification Tests
The most common ‘no heat” call has to do with a malfunctioning flame sensing diode.  Simply turn the meter to microamps DC, hook up, and see if the flame sensing rod is functioning properly.

Frequency
Measure from 10Hz to 40kHz using this range with 1 Hz resolution.

Silicone Leads with Detachable Probe TipsLTCaseStand
Because the wire insulation is silicone, the leads stay flexible in cold weather and will not melt if bumped by a soldering iron. When testing electrical circuits with two hands, there is a risk that a careless mistake may complete a circuit through your body and potentially cause death or injury. Use the either probe clip on rubber boot to connect and firmly hold the V lead in place, detach the COM probe tip, connect an alligator lead tip to COM and ground, and perform a one-hand test more easily than most meters on the market. Built-in lead storage makes it easy to keep everything together from job to job.

Tilt Stand and Magnetic Hanger
One thing we hear from technicians every day is how much they enjoy the magnetic hanger because it keeps the meter out of the way while testing. The LT17A includes the magnet and a tilt stand to give you a choice in the way you want to use it.

Bright Blue Backlight
Easily read the display in overcast conditions or in dimly lit areas.

MAX/MIN hold  
Record the minimum or maximum reading during a measurement. To exit the MIN/MAX function, hold the button for more than 2 seconds

And More:

  • Volts AC.
  • Volts DC.
  • Resistance (Ohms).
  • Diode Test
  • Rugged ABS case with rubber boot.
  • Even though it’s a classic style meter it still fits naturally in your hand.
  • Auto power-off (APO) to conserve battery life.

 

Competitive Advantages

The testing capability packed into this classic style meter is its main competitive advantage. In addition to all of the ranges, it has direct temperature measurement and it works with all of our accessory head instruments to make it one of the most complete classic style meters available for HVACR. Add to that the fact that the classic design still fits naturally in your hand and comes standard with a rugged rubber boot.  We think the boss got it right when he said this is the “Biggest Bang for The Buck”.

What's Included


  • Digital Multimeter - LT17AW
  • Wireless Transmitter - ET2W
  • Current Clam Head - ACH4
  • Deluxe Test Leads - ADLS2
  • K-type Thermocouple - ATB1
  • Large Single Meter Case - ANC9
  • Operator’s manual

AVH1-SRC-product-tmb


Specifications

TECHNICAL SPECIFICATIONS

Wireless Range: Upto 75 feel (23m) line of sight                                                                                                                                                  Wireless Frequency: 910MHz to 920MHz (US), 868.1MHz to 868.5MHz (European)                                                                                   Display: 5000 count liquid crystal display with backlight                                                                                                                                       Auto-off: off after 30 minutes to extend battery.
Indicators: Continuity beeper (<100Ω). Low bat.
Overrange: "OL" or “-OL” is displayed.
Operating environment: 32 to 122°F (0 to 50°C) <70%RH
Storage environment (with batteries removed): -4 to 140°F (-20 to 60°C) <80%RH
Altitude: 6561.7 feet (2000m).
Battery life: 100 hours typical.
Battery type: 9V NEDA 1604 type
Stated accuracies: 74°F±8°F (23°C±4°C), 75%RH
Temperature coefficient: 0.1 x (specified accuracy) 1°F/°C (32 to 66°F (0 to 19°C), 82 to 122°F (28 to 50°C)).

DC Voltage
Ranges: 500mV, 5000mV, 50V, 500V, 600V
Resolution: 0.1mV
Accuracy: 0.5%±3
Input impedence: 10MΩ

AC Voltage (50Hz-500Hz)
Ranges: 500mV, 5000mV, 50V, 500V, 600V
Resolution: 0.1mV
Accuracy: 1.2%±6(500mV to 50V ranges), 2%±6(500V and 600V ranges)
Input impedence: 10MΩ

DC Current (through meter)
Ranges: 500μA, 50mA, 500mA
Resolution: 0.1μA
Accuracy: 1.0%±1
Voltage burden: 800mV

AC Current (through meter)
Ranges: 500μA, 50mA, 200mA
Resolution: 0.1μA
Accuracy: 1.5%±4
Voltage burden: 800mV

Frequency (autoranging)
Range: 10Hz to 40KHz
Resolution: 1Hz
Sensitivity: 3.5V rms min
Accuracy: 0.1%± 3

Resistance (ohms)
Ranges: 200Ω, 2kΩ, 200kΩ, 20MΩ
Resolution: 0.1Ω
Accuracy: 1.0%±4 (200Ω to 200kΩ ranges),
2.0%±4 (20MΩ range)
Open circuit voltage: 0.3VDC typical, (2.5VDC on 200Ω)

Diode Test
Accuracy: 1.5%±3
Test current: 0.5mA approx.
Open circuit voltage: 2.5VDC typical

Capacitance (MFD)
Ranges: 20μF, 200μF, 2kuF
Resolution: 0.01μF
Accuracy: 4%±10
Test frequency: 21Hz
Test voltage: <3.0V

Temperature
Ranges: -30 ~ 1400°F (-35 ~ 750°C)
Resolution: 0.1°F, 0.1°C
Accuracy: ±(1°F) 32 ~ 120°F
±(1.0%+1.5°F) 32°F ~ 750°F
±(3.0%+4°F) -30 ~ 32°F, 750 ~ 1400°F
±(1°C ) 0°C ~ 49°C; ±(1.0% + 1°C) 0°C ~ 399°C;  ±(3.0% + 3°C) -35°C ~ 0°C;  400°C ~ 750°C Sensor type: K-type thermocouple

Field Calibration (temp offset pot)
The LT17AW can be easily calibrated on the job. Use a bucket of ice water to have a known 32°F (0°C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0).

Fuse Replacement: When only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection values below. If that doesn’t work visit our Warranty Page.to check for other problems.

Overload Protection
VAC/DC:   
 
(500mV range )   600VAC/DC rms for 15 sec
(>500mV range)  600VAC/DC rms
AAC/DC: 0.25A/500V fuse (6.3X32mm)
Capacitance: 0.25A/500V fuse (6.3X32mm) model RFM66
Temperature: 30VAC/DC rms
Resistance: 500VAC/DC rms
Diode Test: 500VAC/DC rms
Continuity: 500VAC/DC rms

 

 

Normal 0 false false false MicrosoftInternetExplorer4

Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999. 

Overrange: (OL) or (-OL) is displayed.

Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.

Measurement rate: 2.5 times per second, nominal.

Operating Environment: 0°C to 40°C at < 70% relative humidity.

Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.

Auto power off: 15 seconds approx.

Standby consume current: <10μA

Battery: 4 pcs 1.5V (AAA size) UM-4 R03. 

Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor). 

Dimensions: 170mm(H) x 44mm(W) x 40mm(D). 

Weight: 160g including batteries.

 

ELECTRICAL

Range: 20MW, 2000 MW.

Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.

Accuracy:

20 MW range: ±(2%rdg + 2dgts)

2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)

>500 MW ±(5%rdg + 2dgts)

Rated voltage: DC-DC converter to 1000VDC

Accuracy temperature: 23°C ± 5°C less than 70%RH

Temperature Coefficient: 0.1X (specified accuracy)/°C (28°C)