 User's Manual
Product Flyer
Package Art
Features and Benefits
Competitive Advantages
What's Included?
Recommended
Specifications
What is It?
Dual-Display Mini Clamp Meter for HVAC/R– Read Amps and Volts at the Same Time - model SC52 Read amps and volts at the same time with the Dual-Display Mini Clamp Meter for HVAC/R, model SC52. Measure any other range on the meter simultaneously with an amp measurement. The SC52 is compact measuring only about 8-inches, easy to use and includes many of the ranges you use everyday during HVAC/R field service. It includes the ranges for flame diode rectification and a diode test for checking circuits, as well as built-in safety features like non-contact voltage, a hold button and a continuity tester with audible alarm.
How Does it Work?
The SC52 is an auto ranging DMM that with a dedicated amp clamp and display, as well as a display for the rest of the ranges on the meter. When you select a range and hook up to the circuit, the SC52’s bottom display automatically includes symbols or proper decimal places for the range you are testing. If you are out of the given range on this meter you will receive and “OL” message. The push button non-contact voltage feature allows you to determine whether a line is hot or not right on the meter.
Selecting Ranges The following is a look at all of the functions found the SC52 Dual Display DMM for HVAC/R. For DC voltage, set the meter to the VDC parameter instead of VAC (shown below).
|
Voltage

Resistance

Diode

|
AAC

Microamps DC

|
Features and Benefits
The SC52 is unique. Not in that it has a dual-display, but in the fact that it has a dual-display and it was made for the work you do, the way you do it. It includes features and benefits for HVAC/R that really stand out:.
Dual-Display The SC52 display allows you to read amperage while testing any other function on the dial. More tests at one time means the job gets done right and the job gets done faster,
Non-contact Voltage With the NCV tab on the tip of the clamp close to an AC voltage, press and hold the NCV button. The NCV LED will light with an analog feel and the beeper will beep. The closer you get to AC voltage, the louder the beep. The NCV function is sensitive enough to detect 24VAC on thermostats (24V to 600V, 50Hz to 60Hz).
400AAC Using the built-in amp clamp, read 0-400 amps directly on your meter with 0.1 resolution.
Microamps DC - Flame Rectification Tests The most common ‘no heat” call has to do with a malfunctioning flame sensing diode. Simply turn the SC52 to microamps DC, hook up, and see if the flame sensing rod is functioning properly.
Wire Grabbing Jaw The amp clamp is shaped like a jaw to make grabbing a single wire easy using only one hand.
Hold The HOLD button is easily pressed with your thumb while holding the mini clamp meter naturally in your hand. It holds any reading on your SC52 so you can concentrate on the test points and look at the LCD after you’ve disconnected.
And More:
- Volts AC.
- Volts DC.
- Resistance (Ohms).
- Diode Test
- Continuity.
- Rugged ABS case.
- Ergonomic shape fits naturally in your hand.
- Auto power-off (APO) to conserve battery life.
- Compact - under 8” tall.
Competitive Advantages
The SC52 has features and benefits that rival many full-size clamp-on multimeters it also has safety features to help protect you during field service. The built-in non-contact voltage sensor (NCV) sensor tells you if a line is hot or not before you work on it. The continuity beeper tells you if a circuit is open or closed. The hold button on the side of the SC52 allows you to concentrate on the test point, hold the reading and then look at the display after you’ve disconnected. Safer, a dual-display for faster testing, flame rectification and other HVAC/R ranges, all in a compact meter - it all makes the SC52 a solid choice for field service technicians.
What's Included
- Dual-Display Mini Clamp Meter for HVAC/R - SC52
- Vinyl Test Leads
- Mini Clamp-On Meter Case - ANC4
- Three (3) 3V lithium-ion CR2032 batteries (installed)
- Operator’s manual
|
|
Recommended Accessories and Replacement Parts
Technicians who like the SC52 may also enjoy these instruments and accessories:
|

|
True RMS Clamp Meter with Temperature, Capacitance and Backlight - SC77
The SC77 is one of our most popular digital multimeters for a reason. It has virtually every parameter for electrical and thermal HVAC/R testing in one meter. This auto ranger includes a host of safety features including a high-voltage LED and beeper, a continuity warning, push button non-contact voltage (NCV), a lead holder with detachable leads and alligator probe tips for easy one-handed testing. As far as ranges go, it has temperature, capacitance, microamps DC for flame diode tests, and everyday electrical ranges for HVAC/R. Not to mention technicians tell us it one of the most durable meters in the industry. Rivaled only by our stick meters, the SC77 is also one of their top picks from Fieldpiece.
Read More..
|
|

|
Expandable True RMS Stick Multimeter with Backlight - HS36
Our top of the line True RMS Stick Meter, the HS36 includes the ranges you use everyday for HVAC/R field service plus includes a bright blue backlight and True RMS. Like the rest of the HS30 series, the HS36 comes equipped with a magnetic hanger, along with detachable silicone test leads and alligator clip probe tips for remote and easy one-handed testing, as well as the full set of built-in safety features. This auto-ranging stick meter also includes a bar graph on the LCD for an analog feel. Technicians who prefer our expandable stick meters tell us this is the best digital multimeter for HVAC/R field Service.
Read More..
|
|

|
Dual-Temperature Meter - ST4
The Fieldpiece Dual-Temperature Meter, model ST4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ST4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ST4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 in big numbers on the LCD screen. Features two front face calibration pots and comes in our clear front case with magnetic hanger model ANC6. Use with our optional ATWB1 wet bulb thermocouple to help you find target superheat or with our pipe clamp T/Cs to check for blocked dryer filters.
Read More.. |
|

|
Large Briefcase-Style Instrument Bag - ANC3
The ANC3 Large Briefcase-Style Instrument Bag is our top of the line instrument case. Combined with our modularly expandable instruments and accessories, the ANC3 can haul a service truck full of tools to your job, over your shoulder. It has 14 pockets in all. It holds most any combination of your Fieldpiece gear: 3 meters and 10 accessory head instruments with room for plenty more, or, put in 6 standalones and their accessories, 2 meters and more. The combinations are almost endless. One thing’s for sure, you can fit the test instruments you need to do the whole job easier, better and faster with the ANC3 over your shoulder. Features include rugged nylon construction, padding, durable pockets inside and out, a rugged zippers and a shoulder strap. Comes standard with our big Fieldpacks and doubles as a great laptop briefcase.
Read More..
|
Specifications
TECHNICAL SPECIFICATIONS Display: 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999. Overrange: "OL" or “-OL” mark indication. Auto power off: 10 minutes. Operating environment: 32 to 122°F (0 to 50°C), at <70% R.H. Storage temperature: -4 to 140°F (-20 to 60°C), @ <80% R.H. with batteries removed. Accuracy: Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), <75% relative humidity. Temperature coefficient: 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C). Altitude: 6561.7 feet (2000m). Jaw opening capability: 30mm (diameter) conductor Power: Three lithium-ion CR2032 3V batteries. Battery life: 100 hours typical for lithium-ion on AAC (top display), 75 hours typical for lithium-ion on dial functions (bottom display). Accessories: One pair vinyl test leads, ATB1 k-type thermocouple, (3) 3V CR2032 batteries (installed), ANC4 carrying case, and operating instructions. Safety: IEC/EN 61010-1 (UL61010-1) CATIII 600V and IEC/EN 61010-2-032 (UL61010-2-032) CATIII 300V, class II and pollution degree 2 indoor use comply with CE, C-tick certified.
DC Volts Ranges: 4V, 40V, 400V, 600V Resolution: 1mV Accuracy: ±(0.5% rdg + 2 dgts) Input impedance: 4V: 10MΩ 40V~600V: 9.1MΩ
AC Volts (50Hz - 500Hz) Ranges: 4V, 40V, 400V, 600V Resolution: 1mV Accuracy: ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range Input impedance: 4V: 10MΩ 40V~600V: 9.1MΩ Minimum test time for stable reading: 2 seconds
Resistance Ranges: 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ Resolution: 0.1Ω Accuracy: ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range Open circuit volts: -0.45VDC typical, (-1.2VDC on 400Ω range) Minimum test time for stable reading: 2 seconds
AC Current (50Hz - 60Hz) Ranges: 40A, 400A Resolution: 0.01A Accuracy: ±(2.0% rdg + 6 dgts)
DC Current Ranges: 400μA, 4000μA Resolution: 0.1μA Accuracy: ±(1.0% rdg + 2 dgts) Voltage burden: 1V (8V on 4000μA range)
Continuity Range: 400Ω Resolution: 1Ω Audible indication: Less than 25Ω Response time: 500ms
Diode Test Test current: 1.2mA (approximate) Accuracy: ±(3.0% rdg + 3 dgts) Resolution: 10mV Audible indication: Less than 0.25V Open circuit volts: 3.0VDC typical
Overload Protection (no fuses to replace) VAC/DC 600VDC or AC RMS AAC 400 AAC Resistance 500VDC or AC RMS Continuity 500VDC or AC RMS Diode 500VDC or AC RMS μADC 500VDC or AC RMS
Normal 0 false false false MicrosoftInternetExplorer4
Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999.
Overrange: (OL) or (-OL) is displayed.
Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.
Measurement rate: 2.5 times per second, nominal.
Operating Environment: 0°C to 40°C at < 70% relative humidity.
Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.
Auto power off: 15 seconds approx.
Standby consume current: <10μA
Battery: 4 pcs 1.5V (AAA size) UM-4 R03.
Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor).
Dimensions: 170mm(H) x 44mm(W) x 40mm(D).
Weight: 160g including batteries.
ELECTRICAL
Range: 20MW, 2000 MW.
Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.
Accuracy:
20 MW range: ±(2%rdg + 2dgts)
2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)
>500 MW ±(5%rdg + 2dgts)
Rated voltage: DC-DC converter to 1000VDC
Accuracy temperature: 23°C ± 5°C less than 70%RH
Temperature Coefficient: 0.1X (specified accuracy)/°C (28°C)
|