Mini Clamp Meter for HVAC/R - SC44

The Mini Clamp Meter for HVAC/R, model SC44, is a basic, affordable clamp-on meter designed for HVAC/R field service.User's Manual

Products Flyer

Package Art

Features and Benefits

Competitive Advantages

What's Included?

Recommended

Specifications

 

 

 

 

What is It?

Mini Clamp Meter for HVAC/R - Compact and Affordable - SC44
The SC44 Mini Clamp Meter for HVAC/R is a basic, affordable clamp-on meter designed for HVAC/R field service. It measures Amps AC, Volts AC, Volts DC, resistance, continuity, and includes a diode check.  A built-in Non-Contact Voltage (NCV) sensor allows you to test thermostats and circuits to see if they’re hot or not. The range button  (Looks like a two ring bulls eye) switches the SC44 between a manual ranging meter and an auto ranger. The small size fits easily in your hand. Keep it in glove box as a backup meter or hang it on your belt to take measurements in tight places. The SC44 is Cat.III 600V rated.

 

How Does it Work?

Check to see if the circuit is hot using the Non-Contact Voltage (NCV) button. Use the wire grabbing jaw to easily separate wires when taking current readings.  Switch to AAC to test. Select any other range and use the included test leads to measure.

Selecting Ranges
For DC voltage, set the meter to the VDC parameter instead of VAC (shown below). For all ranges choose a range just above the value you expect. If display reads “OL” (overload), select a higher range. If display shows less than three numbers, select a lower range for better resolution.

Voltage

SC44v01-volts

Resistance

SC44v01-resistance

Amps AC

SC44v01-AAC

 

Features and Benefits

While this is a basic HVAC/R multimeter, it is backed by the Fieldpiece name. We designed it to be as durable as our big meters during field service calls. It also gives you the choice of manual or auto ranging with the push of a button.  The built-in non-contact voltage sensor range works on thermostats and larger lines.  It’s compact, easy to use and comes with a Cat. III 600V rating unlike many similarly priced meters.  

Non-contact Voltage
With the NCV tab on the tip of the clamp close to an AC voltage, press and hold the NCV button. The NCV LED will light with an analog feel and the beeper will beep. The closer you get to AC voltage, the louder the beep. The NCV function is sensitive enough to detect 24VAC on thermostats (24V to 600V, 50Hz to 60Hz). 

400AAC
Using the attached amp clamp, read 0-400 amps directly on your meter with 0.1 resolution.

Wire Grabbing Jaw
The amp clamp is shaped like a jaw to make grabbing a single wire easy using only one hand.

Hold  
The HOLD button is easily pressed with your thumb while holding the mini clamp meter naturally in your hand. It holds any reading on your SC44 so you can concentrate on the test points and look at the LCD after you’ve disconnected.

And More:
  • Volts AC.
  • Volts DC.
  • Resistance (Ohms).
  • Continuity.
  • Diode Test.
  • Rugged ABS case.
  • Ergonomic shape fits naturally in your hand.
  • Auto power-off (APO) to conserve battery life.
  • Under 8” tall.

Competitive Advantages

The SC44, while a basic mini clamp-on meter, it’s a solid performer and built exclusively for the work you do. Other small meters often lack the durability, ranges, ratings and resolution you need in a good backup meter. Like all of our clamp meters, the SC44 includes the built-in Non-Contact Voltage (NCV) tester, to save you time during a service call and space in your pocket or tool bag.

What's Included


  • Mini Clamp Meter for HVAC/R - SC44
  • Vinyl Test Leads
  • Mini Clamp-On Meter Case – ANC4
  • Two (2) 1.5V “AAA” batteries (installed)
  • Operator’s manual

SC44


Recommended Accessories and Replacement Parts

Technicians who like the SC44 may also enjoy these instruments and accessories:

 

SC77-SRC-product-tmb

 

True RMS Clamp Meter with Temperature, Capacitance and Backlight - SC77

The SC77 is one of our most popular digital multimeters for a reason. It has virtually every parameter for electrical and thermal HVAC/R testing in one meter. This auto ranger includes a host of safety features including a high-voltage LED and beeper, a continuity warning, push button non-contact voltage (NCV), a lead holder with detachable leads and alligator probe tips for easy one-handed testing. As far as ranges go, it has temperature, capacitance, microamps DC for flame diode tests, and everyday electrical ranges for HVAC/R. Not to mention technicians tell us it one of the most durable meters in the industry. Rivaled only by our stick meters, the SC77 is also one of their top picks from Fieldpiece.

Read More..

HS36-SRC-product-tmb

Expandable True RMS Stick Multimeter with Backlight - HS36

Our top of the line True RMS Stick Meter, the HS36 includes the ranges you use everyday for HVAC/R field service plus includes a bright blue backlight and True RMS. Like the rest of the HS30 series, the HS36 comes equipped with a magnetic hanger, along with detachable silicone test leads and alligator clip probe tips for remote and easy one-handed testing, as well as the full set of built-in safety features.  This auto-ranging stick meter also includes a bar graph on the LCD for an analog feel. Technicians who prefer our expandable stick meters tell us this is the best digital multimeter for HVAC/R field Service.

Read More..

ADK7-SRC-product-KIT-tmb

Deluxe Silicone Test Lead Kit - ADK7

The ADK7 deluxe silicone lead is the optimal way to test most electrical parameters you run into during field service. The kit includes the ADSL2 silicone leads and ASA2 alligator leads plus our all new RCT2 "Molex"-style probe tips. HVAC techs often remove the black probe tip (common) and insert the black alligator lead for an extended reach from ground. When used with our stick meters, the Volts (red) probe tip is inserted into the top of the meter for easy one-handed testing. Use both alligator extension to perform “no-hands” tests. Silicone test leads deliver better performance in temperature extremes than test leads insulated with vinyl.

Read More..

ANC3-SRC-product-tmb

Large Briefcase-Style Instrument Bag - ANC3

The ANC3 Large Briefcase-Style Instrument Bag is our top of the line instrument case. Combined with our modularly expandable instruments and accessories, the ANC3 can haul a service truck full of tools to your job, over your shoulder. It has 14 pockets in all. It holds most any combination of your Fieldpiece gear: 3 meters and 10 accessory head instruments with room for plenty more, or, put in 6 standalones and their accessories, 2 meters and more. The combinations are almost endless. One thing’s for sure, you can fit the test instruments you need to do the whole job easier, better and faster with the ANC3 over your shoulder. Features include rugged nylon construction, padding, durable pockets inside and out, a rugged zippers and a shoulder strap. Comes standard with our big Fieldpacks and doubles as a great laptop briefcase.

Read More..


Specifications

TECHNICAL SPECIFICATIONS
Display: 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
Range: Manual ranging mode (SC44 & SC45), hold button for 2 seconds to return to autoranging mode.
Overrange: "OL" or “-OL” mark indication.
Auto power off: 10 minutes.
Operating environment: 32 to 122°F (0 to 50°C), at <70% R.H.
Storage temperature: -4 to 140°F (-20 to 60°C), @ <80% R.H. with batteries removed.
Accuracy: Specifications good in ambient conditions of 74°F ±8°F (23°C ±4°C), <75% relative humidity.
Temperature coefficient: 0.1×(specified accuracy) per °F/°C; 32 to 66°F (0 to 19°C); 82 to 122°F(28 to 50°C).
Altitude: 6561.7 feet (2000m).
Power: Two AAA 1.5V batteries.
Battery life: 400 hours typical with alkaline.
Accessories: One pair test leads, (2) 1.5V AAA batteries (installed), carrying case and operating instructions.
Safety: Designed to meet IEC61010-1 (EN61010-1) and IEC61010-2-032 (EN61010-2-032), clamp is CATIII 300V, class II, voltage Cat.III 600V, and pollution degree 2 indoor use comply with CE, C-tick certified, UL listed..

DC volts
Ranges: 400mV, 4V, 40V, 400V, 600V
Resolution: 0.1mV
Accuracy: ±(0.5% rdg + 2 dgt)
Input impedance:
400mV > 100MΩ, 4V = 10MΩ, 40V~600V = 9.1MΩ
Transient protection: 6kV for 10μ sec

AC volts (50Hz - 500Hz)
Ranges: 4V, 40V, 400V, 600V
Resolution: 1mV
Accuracy: ±(1.2% rdg + 5 dgts), ±(1.5% rdg + 5 dgts) on 600V range
Input impedance: 4V = 10MΩ, 40V~600V = 9.1MΩ

Resistance
Ranges: 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
Resolution: 0.1Ω
Accuracy:
±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges
±(1.5% rdg + 4 dgts) on 4MΩ range
±(3.0% rdg + 5 dgts) on 40MΩ range
Open circuit volts: -0.45VDC typical, (-1.2VDC on 400Ω range)

AC Current (50Hz - 60Hz)
Ranges: 40A, 400A,
Resolution: 0.01A
Accuracy: ±(2.0% rdg + 6 dgts)

Continuity
Audible indication: Less than 25Ω
Response time: 500ms

Diode Test
Test current: 1.2mA (approximate)
Accuracy: ±(3.0% rdg + 3 dgts)
Resolution: 10mV
Audible indication: Less than 0.25V
Open circuit volts: 3.0VDC typical

Overload Protection
VAC/DC - 600VDC or AC RMS
AAC - 400AAC
Resistance - 500VDC or AC RMS
Continuity - 500VDC or AC RMS
Diode - 500VDC or AC RMS

Display: 3 1/2 digit liquid crystal display (LCD) with maximum reading of 1999.

Overrange: (OL) or (-OL) is displayed.

Low battery indication: The battery symbol is displayed when the battery voltage drops below the operating level.

Measurement rate: 2.5 times per second, nominal.

Operating Environment: 0°C to 40°C at < 70% relative humidity.

Storage Temperature: -20°C to 60°C, 0 to 80% R.H. with battery removed from meter.

Auto power off: 15 seconds approx.

Standby consume current: <10μA

Battery: 4 pcs 1.5V (AAA size) UM-4 R03.

Battery Life: 4 hours (continuity) typical with alkaline battery (@20ÌÙ range test 10ÌÙ resistor).

Dimensions: 170mm(H) x 44mm(W) x 40mm(D).

Weight: 160g including batteries.

 

ELECTRICAL

Range: 20MW, 2000 MW.

Resolution: 10K W on 20MW range, 1 MW on 2000 MW range.

Accuracy:

20 MW range: ±(2%rdg + 2dgts)

2000 MW range: <500ÌÙ ±(4%rdg + 2dgts)

>500 MW ±(5%rdg + 2dgts)

Rated voltage: DC-DC converter to 1000VDC

Accuracy temperature: 23°C ± 5°C less than 70%RH

Temperature Coefficient: 0.1X (specified accuracy)/°C (<18°C or >28°C)