| Use
your digital multimeter, data logger, or handle to measure parameters
needed by HVAC/R technicians. Fieldpiece accessories work with
meters that have mV (AC and DC) ranges and industry standard input
jacks. Use the Fieldpiece deluxe test leads or the convenient
AHDL1 adapter handle to connect any accessory head to most digital
multimeters.
For most heads, set your meter to mVDC and read the LCD directly.
|
|
|
Measures to 400AAC.
- Current range:
1A to 400A rms.
- Accuracy: ±1.5%rdg
+ 1dgt.
- Maximum conductor
size:
0.91 inches (23mm).
|
| |
| AVG2
Digital Vacuum Gauge |
Displays pressure
in microns in steps of 1 micron. Has pump down indication showing progress
from atmospheric pressure.
- Range: 50 to
2000 microns of mercury.
- Resolution:
1 micron of mercury.
- Pump down indication:
when pumping down from atmospheric pressure to 2000 microns, output
of head goes from over 3VDC to 2VDC.
- Straight-in
access to sensor for easy cleaning.
- Fitting: 1/4"
flared brass fitting (male)
- Accuracy (@~75ºF):
±10%, 0-1000 microns of mercury
- Auto-off can
be disabled for data logging.
- "T"
for inline vacuum testing.
|
| |
| Which
temperature head? |
| For
air temperatures, use the ARH4 or the AAV3. When it's not practical
to touch the test point (e.g. a ceiling vent), use the ATIR3 infrared
head. Infrared is not recommended for pipe temperatures. For comparing
temperatures (two temperatures at once) use the ATH4 with any k-type
thermocouple with the small industry standard fork. |
|
| AAV3
Air Velocity with Temperature Head |
Measures air velocity.
Use to estimate CFM. Does not replace a hood for precision CFM measurements.
Air velocity:
- Fft/min, meters/sec,
MPH, KM/hr.
- Range: 80 to
5900 ft./min.
- Accuracy: +/-3%fs+1dgt.
Temperature
- Displays ºF
and ºC.
- Range: -4ºF
to 140 ºF.
- Accuracy: +/-1ºF
from 32ºF to 113ºF.
- Resolution: 0.5ºF.
Max operating
temp: 120ºF.
Output: 1mV/unit of measure
(1mV/100ft/min above 2000 fpm). |
|
| ARH4
Wet Bulb and Dew Point Head |
Measures air temperature
and RH% and displays wet bulb and dew point.
- +/-1ºF
32ºF-113ºF.
- +/-2.5% RH,
10% to 90%RH @ 77ºF.
- SelectºF
or ºC.
- Auto-off can
be disabled for
data logging.
|
|
| ATH4
Dual Temperature Head |
Two k-type thermocouple
inputs. Display T1, T2, or T1-T2.
- Field calibration
for ±1ºF accuracy.
- Displays ºF
directly at 0.1ºF resolution on DMM with 0.1mVDC resolution.
- Select ºF
or ºC.
- Converts from
-50ºF to 1800ºF (optional thermocouple required)
- Includes two
“wrap tab” thermocouples plus velcro straps. Thermocouples
insulated to 400ºF.
- Auto-off can
be disabled for data logging.
|
|
| ATIR3
Non-contact (Infared) Surface Temperature Head With Laser Sight |
- Measures temperature
without contact.
- 8:1 field of
view.
- Laser sight included.
- Select ºF
or ºC.
- Operating ambient
temp: 32ºF to 122ºF at <75%RH.
- Temperature
measurement range: 0ºF to 752ºF.
- Accuracy: Whichever
is greater. At 73ºF ± 10ºF at <90%RH
±2.0%rdg or 4ºF, 32ºF to 160ºF
±3.0%rdg or 5.5ºF, 0ºF to 31ºF,
161ºF to 752ºF.
|
| |
| |
| To
check levels of carbon monoxide use the ACM3. An AMN2 manometer can
be used to ensure you have proper gas line and manifold pressure. An
AUA2 can ensure that the flame diode circuit is functioning properly
and not causing the furnace to "lock-out". The AOX2 accessory
head measures %O2 of flue gas. It also displays
%CO2. The ADMN2 is a dual port manometer, which
allows the user to measure pressure drop. Use the ADMN2 to make sure
the conditioned space has a positive pressure, keeping combustion products
out. |
|
| ACM3
Carbon Monoxide Head |
Measures CO in air
and finds CO sources.
- Fast enough
to locate CO source in
“walk-around” test.
- Three pin sensor
for better performance.
- Long battery
life.
- Optional
Pump (ACMP3).
- Auto-off can
be disabled for data logging.
- Select averaging
or normal for smoothing or fast response to change.
- Range: 0 to
1000PPM (2000PPM with
5 minute max exposure time).
- Initial accuracy:
0-15ppm ±5% reading
±1 ppm after zeroing;15-35ppm
±5% reading ±2 ppm after zeroing;
0-1000ppm ±5% reading ±5 ppm
after zeroing.
- Response time:
<70sec to 90% of reading.
- Operating temperature:
32 to 105 ºF.
- Sensor type:
Electrochemical (specific to CO).
|
| |
ACMP3
Pump |
|
| AMN2
Manometer (Pressure) Head |
Measures gas pressure
and has resolution low enough for static pressure.
- Maximum 20"
WC (water column) for gas pressure.
- 0.01" WC
resolution for static pressure.
- Manual zero-set
for comparing two pressures.
- Includes tube
and adapter for gas pressure measurement.
- Auto-off can
be disabled for data logging.
|
|
| ADMN2
Dual Port Manometer (Pressure) Head |
The ADMN2 is a dual
port manometer accessory head that measures differential, absolute,
and static pressure.
- Range from -60.0"WC
to 60.0"WC.
- Accuracy of
±1.5% FS.
- Resolution down
to 0.01"WC for static pressure measurements.
|
|
|


|
| AOX2
Combustion Check Head |
The AOX2 is a flue
gas measurement accessory head. Find flue gas temperature, %CO2,
%O2 for two fuel types.
- Includes high-temperature
K-type thermocouple and pump with an inline water trap and filter.
- Fuel types: Gas
and Oil
- Range: 0 to 25(%CO2,
%O2), -58°F to 1000°F (temp)
- Resolution: 0.1(%CO2,
%O2) and 0.1°(temp)
- Accuracy (CO2,
O2): ±0.3%
- Accuracy (temp):
±0.6%+3°F (1.7°C) after field calibration
Click here
to download the Combustion Efficiency Worksheet which works with the
AOX2. |
|
| AUA2
Milliamps & Microamp Head |
Measures milliamps
and microamps for flame diode test. Measures 4 to 20mA control circuits.
- Includes flame
diode adapter kit (AQK3).
- Resolution:
0.1 for meters with 0.1mVDC.
- Accuracy:
DC: ±(1.0%rdg + 1dgt)
AC: ±(1.5% + 2dgts).
- Max current:
200mA
AC or DC.
|
| |
| Superheat
and Subcooling Heads |
| Most
non-electrical HVAC/R problems are charge related. Many systems in operation
are undercharged or overcharged. This can cause decreased efficiency
and compressor failure. The higher the efficiency of a system, the more
critical it is that it is charged properly. |
| 
|
| ASH3
Superheat Head w/K-type TC |
Measures refrigerant
pressure and temperature and calculates superheat for two refrigerants
in English or metric units.
- Display pressure
in PSI or kPa.
- Display temperature
in ºF or ºC.
- Display superheat
in ºF or ºC.
- Select R22 or
R410A.
- Auto-off can
be disabled for data logging.
NEW FEATURES
- Includes "T".
- Now accepts K-type
thermocouples. ATC1 included.
- LED indicates
when readings are stable.
- Thermocouple
calibration pot.
- Atmosphere pressure
calibration.
ATC1
|
| 
|
| ASX14
Superheat and Subcooling Head for A/C |
Measures refrigerant
pressure and temperature and calculates superheat or subcooling for
R22 and R410A in English or metric units.
- Display pressure
in PSI or kPa.
- Display temperature
in ºF or ºC.
- Display superheat
in ºF or ºC.
- Display subcooling
in ºF or ºC.
- Select R22 or
R410A.
- Auto-off can
be disabled for data logging.
NEW FEATURES
- Includes "T".
- Now accepts K-type
thermocouples. ATC1 included.
- LED indicates
when readings are stable.
- Thermocouple
calibration pot.
- Atmosphere pressure
calibration.
ATC1
|
| 
|
| ASX24
Superheat and Subcooling Head for Refrigeration |
Measures refrigerant
pressure and temperature and calculates superheat or subcooling for
R134A and R404A in English or metric units.
- Display pressure
in PSI or kPa.
- Display temperature
in ºF or ºC.
- Display superheat
in ºF or ºC.
- Display subcooling
in ºF or ºC.
- Select R134A
or R404A..
- Auto-off can
be disabled for data logging.
NEW FEATURES
- Includes "T".
- Now accepts K-type
thermocouples. ATC1 included.
- LED indicates
when readings are stable.
- Thermocouple
calibration pot.
- Atmosphere pressure
calibration.
ATC1
|
| |
| Accessories
for Miscellaneous Electrical Applications |
|
| AMD1
Microwave Oven Diode Tester Head |
Tests high voltage
diodes commonly found to fail in microwave ovens. Diode test on DMM
cannot test high voltage diodes.
- Contains 9V
battery to test high voltage diodes.
- Identifies opens,
shorts, and correct voltage drop.
|
|
Records voltage
using DL2 data logger or EHDL1 handle.
- Accuracy: DC:
±(0.5%rdg +
1 dgt); AC: ±(1.0%rdg + 4 dgts).
- Max voltage:
600V AC or DC.
- Input impedance:
1MOhm.
- Standard test
leads plug in top.
|
|
| ACDC6
AC & DC Current Clamp |
Connect to any digital
multimeter with industry standard jacks to measure AC or DC current
up to 600A. Reads amps directly on any Fieldpiece meter so there’s
no need to mentally move decimal points.
- DCA accuracy:
+/-(2%rdg+2A).
- ACA accuracy@60Hz,
<400A:
+/-(2%rdg+2A).
- ACA accuracy@60Hz,
>400A:
+/-(6%rdg+2A).
- Jaw opening:
30mm.
|
| |
|
|
|