Connect Fieldpiece accessory heads to our “stick” meter, data logger, electronic handle, or other DMMs to measure HVAC/R parameters. The Fieldpiece HS series “stick” HVAC Multimeters connect directly to accessory heads by sliding the head right onto the meter. Use the EHDL1 handle to convert any head to a stand alone meter. Fieldpiece accessory heads can be used with most other DMMs. Your meter only needs mV (AC and DC) ranges and industry standard input jacks. Use the Fieldpiece deluxe test leads (ADLS2) or the convenient AHDL1 adapter handle to connect the head to your meter. Technicians also use Fieldpiece temperature, superheat and subcooling, combustion check and carbon monoxide and amp clamp accessory heads to input data into the HVAC Guide® System Analyzer automatically. Simply connect the accessory head instrument onto the top of the HVAC Guide, select the parameter you want to test, and hit enter on the input form.
 |
In Duct Hot-wire Anemometer & Psychrometer Accessory - AAT3
The AAT3 is a hot-wire anemometer and psychrometer combined in one accessory head. The AAT3 gets into ducts easily with its 38" telescoping probe for measurements of air velocity, temperatures, and %RH. It also calculates wet bulb and dew point. When connected to the HG3 (either directly or through a wireless transmitter) the AAT3 provides data for automatic calculations of target superheat, target evaporator exit temperature, and total CFM tests.
Read more...
|
 |
Anemometer - Air Velocity and Temperature Accessory - AAV3
The AAV3 is an anemometer accessory head for use with our modular instruments that measures air velocity and temperature in English or Metric units: Ft/min, M/s, MPH, KM/hr, ºF (degrees Fahrenheit) or ºC (degrees Celsius). Multiply your air velocity by the register’s free area to estimate CFM or diagnose duct blockages and quickly check the airflow balance in a conditioned space. Use with our DL3 Data Logger to track airflow or temperature over time. Features average and real time testing modes.
Read More..
|
 |
600 AAC / ADC Current Clamp Accessory – ACDC6
The ACDC6 is a high-current AC / DC Current Clamp Accessory that gives technicians more flexibility when testing line current. Measures up to 600A AC or DC. The clamp enables most multimeters to measure current without breaking the circuit. The jaw opens to 1.18 inches (3 cm). A coiled cable keeps clutter out of the testing area, Quickly zero out the clamp using the adjustable dial on the face. Use with any multimeter with industry standard Volt and COM jacks and mV AC and DC ranges. Green mechanical contractors tell us they are also using the clamp to measure high-current lines on integrated solar panel powered HVAC / hot water systems.
Read More..
|
 |
400AAC Amp Clamp Accessory – ACH4
The ACH4 current clamp is a small size accessory head for quickly reading up to 400 AC amps. The new claw feature at the top of the clamp allows for quickly picking out the wire you need to measure and isolating it in the clamp. Once the current carrying conductor is isolated, the amperage is converted to mVAC for reading directly on the meter. The ACH4 works with the Fieldpiece “Stick” meter, EHDL1 Electronic Handle, DL3 Data Logger, the HVAC Guide® System Analyzer or any other digital multimeter (with mVAC range) connected by Fieldpiece ADLS2 detachable silicone leads or AHDL1 handle adapter.
Read More.. |
 |
Carbon Monoxide Detector Accessory - ACM3
The ACM3 is a carbon monoxide detector (CO detector) accessory head for use with our modular instruments that measures CO in parts per million (ppm). Its electrochemical sensor is fast enough for walk-around tests. Features and benefits include: Advanced, three-pin sensor that measures 0 to 1000 ppm CO; Calibrate / Zero ACM3 to ambient quickly with the zero calibration pot under the grey rubber strip; Auto Power-Off (APO); Use optional pump (AOXP2) for remote / flue gas testing.
Read More..
|
 |
Dual-Port Manometer Accessory – ADMN2
The ADMN2 is a portable dual port manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure, static pressure and pressure differential. The ADMN2 includes a zero adjust and the Auto Power-Off (APO) function to conserve battery life. Disable APO for data logging. The ADMN2 measures pressure between -60inWC and 60inWC (inches of water column) and -150.0 to 150.0 mBar. The ADMN2 also measures P1 or P2 pressure readings and calculates the difference between P1 and P2. Take static pressure measurements using the resolution mode of 0.01inWC or 0.01mBar.
Read More..
|
 |
Manometer Accessory – AMN2
The AMN2 is a manometer accessory head for use with our modular multimeters (DMMs) and instruments. Measures gas pressure with a resolution for static pressure measurements. The AMN2 includes a zero adjust and the Auto Power-Off (APO) function to conserve battery life. Disable APO for data logging. The AMN2 measures pressure between -60inWC and 60inWC (inches of water column). Take static pressure measurements using the resolution mode of 0.01inWC.
Read More.. |
 |
Combustion Check Accessory - AOX2
The AOX2 is combustion check accessory head that measures % O2 (percent oxygen) and flue gas temperature. It calculates % CO2 (percent carbon dioxide) for two fuel types: gas and oil. Technicians use the AOX2 to sample flue gas on serviced or newly installed equipment. It eliminates the costly, extra tests found on full-function combustion analyzers that technicians often don’t use or need. Match your results to specifications on the data plate or in the manufacturer’s manual to quickly tune furnaces, boilers and more.
Read More..
|
 |
Digital Sling Psychrometer Accessory - ARH4
The Fieldpiece model ARH4 Digital Sling Psychrometer and Hygrometer Accessory Head measures both relative humidity and ambient air temperature. It calculates dew point and wet bulb. It’s great for calculating target superheat as well as logging %RH, temp, WB or DP over time. The head converts %RH, ambient temperature, dew point temperature, and wet bulb temperature to a voltage at a rate of 1 %RH or degree to 1mVDC and your reading is displayed on your meter. The ARH4 snaps directly onto Fieldpiece stick meters, data logger, electronic handles and adapters.
Read More.. |
 |
In Duct Psychrometer Accessory - ARH5
The Fieldpiece model ARH5 In Duct Psychrometer Accessory Head that measures temperatures and %RH in the prime location -- in the duct, near the evaporator. It’s great for calculating target superheat as well as logging %RH, temp, WB or DP over time. The ARH5 snaps directly onto Fieldpiece stick meters, data logger, electronic handles and adapters. Plus techs can get results wirelessly, like indoor wet bulb while they're at the condenser, when they use this accessory head with a wireless transmitter and wireless enabled Fieldpiece meter.
Read More.. |
 |
Superheat and Subcooling Accessory for Air Conditioning – ASX14
The Fieldpiece Superheat and Subcooling Accessory for Air Conditioning, model ASX14, measures suction line, or low side, line temperature and pressure. It then calculates actual superheat in real time using built in P/T charts. It also measures liquid line, or high side, line temperature and pressure, and calculates actual subcooling. Use it to get actual superheat on R-22 and R-410A fixed orifice systems and actual subcooling on TXV / TEV regulated systems. Use the “T” fitting to charge to actual superheat or subcooling by putting the ASX14 in-line between your refrigerant bottle and the system.
Read More..
|
 |
Dual-Temperature Accessory – ATH4
The Fieldpiece Dual-Temperature Accessory, model ATH4, measures two temperatures simultaneously using the included k-type, wrap tab beaded thermocouples. The technology inside the ATH4 provides superior temperature compensation in rapidly changing environments commonly found while performing field service. Use the ATH4 to find Delta T and just about any temperature split you want to measure. Displays T1, T2 and T1-T2 on your Fieldpiece meter, handle or data logger. It is included with the HVAC Guide® System Analyzer to get target superheat and for the Target Evaporator Exit Temperature test. Fieldpiece offers a wide variety of k-type thermocouples for various HVAC specific applications. Use pipe clamp T/Cs with the ATH4 to check for blocked filters. Use wet and dry bulb thermocouples to find target superheat.
Read More..
|
 |
Non-contact Infrared Temperature Accessory with Laser Sight– ATIR3
The Fieldpiece Non-contact Infrared Temperature Accessory with Laser Sight, model ATIR3, collects infrared energy (IR) and converts it to a mVDC signal that is proportional to the temperature being measured. The temperature measured is the average of all the temperatures in the 8:1 cone of viewability. The closer you are to the target, the smaller the area measured. The further away, the larger the area. The digital, non-contact ATIR3 converts the Fieldpiece “Stick” series meter, DL3 data logger, and EHDL1 electronic handle to a one-piece infrared, or IR, thermometer. Use the optional Fieldpiece ADLS2 deluxe silicone test leads or the AHDL1 adapter handle with the ATIR3 for use with DMMs with industry standard jacks.
Read More..
|
 |
Milliamp & Microamp Accessory – AUA2
The Fieldpiece Milliamps & Microamp Accessory, model AUA2, converts microamps (for flame rectifier diode) and milliamps (for heat anticipators and control circuits) to a mV signal for direct current reading on any meter with mV ranges. For resolution of 0.1 micro/milliamps, use a meter that displays 0.1mV. The AUA2 includes quick connect and mini-plug adapters to convert your "stick" meter, DL3 data logger, and EHDL1 electronic handle to a one-piece flame rectifier diode tester and heat anticipator checker.
Read More.. |
 |
Digital Vacuum Gauge Accessory – AVG2
The Fieldpiece Digital Vacuum Gauge Accessory, model AVG2, is a thermistor based digital multimeter accessory that digitally measures a vacuum of 50 to 2000 microns and converts that reading into millivolts DC on your compatible DMM or our electronic handle and data logger. LEDs provide a pump down indicator showing progress from atmospheric pressure. The sensor has been designed to withstand pressures up to 500 psi (3400kPa) so that no damage to the AVG2 will occur if it is exposed to full system pressures.
Read More.. |
 |
Voltage Accessory– AVH1
The Fieldpiece Voltage Accessory, model AVH1, converts volts to millivolts for use with data logger DL3 for direct display and recording of voltage through the meter’s mV scale. Use it with the EHDL1 to record MIN and MAX while freeing up your meter for other tests. Cat III rated. Maximum voltage of 600V AC or DC..
Read More..
|